PARTS & ACCESSORIESGeniSys Universal Solutions Product SheetProduct DescriptionThe Beckett GeniSys™ Advanced Burner Control is a 120 Vac primary safety control for residential and light commercial oil burners used in boiler, furnace, and water heater applications. The GeniSys is used with a suitable cad cell flame sensor to control the oil burner motor, igniter, and optional solenoid valve. It has 24 Vac thermostat terminals (if applicable) compatible with both mechanical and many power stealing thermostats. It can provide interrupted or intermittent duty ignition, and it has a 15-secondlockout time.
GeniSys Control Cross-ReferenceChartBeckettLockoutValve-onMotor-offReplacesReplacesGeniSys ControlDelayDelayTimeHoneywell:Carlin:Part No.Time 2Time 27505A 000015 sec-R7184A, R8184G48245, 0,5B 150015 sec15 sec-R7184B-7505P 151515 sec15 sec15 secR7184P, R7184U 15P 153015 sec15 sec30 secR7184P, R7184U 15P 152M15 sec15 sec2 minR7184P, R7184U 160200 11) Beckett snap-inalarm module required for direct replacement of the control.2) Valve-ondelay and motor-offdelay timings on all models are programmable with Beckett snap-inprogramming display. Other factory set timings are available.
![Beckett Beckett](http://www.manualsdir.com/manuals/651086/7/beckett-7505-page7.png)
Read and download Beckett Cooktop Cooktop Model 7505 User's Manual Page 7 online. Download free Beckett user manuals, owners manuals, instructions, warranties and installation guides, etc. Find great deals on eBay for beckett 7505. Shop with confidence. Skip to main content. EBay Logo: Shop by category. Shop by category. Enter your search keyword. Beckett 7505P1515U, 7505P 1515U GeniSys Advanced Oil Burner Control. Buy It Now +$8.50 shipping.
Contact Beckett for alternate timings.GeniSys Display, 52067UThe GeniSys Display enables the contractor to access the advanced features of the GeniSys Burner Control. It communicates the current status and last fifteen cycles of history for ease of diagnostics. The Tool also allows the contractor to program the pretime and post-timedelay timings, making the GeniSys a universal control.GeniSys Contractor Tool, 52082UThe GeniSys Contractor Tool, with its sturdy shock absorbing design, is made for the contractor’s toolbox. The Tool provides the same functions as the GeniSys Display.GeniSys Lockout Alarm, 52040UThe GeniSys Lockout Alarm provides dry contacts for use with an alarm system requiring contact closure in the event of a soft or hard lockout of the GeniSys Control.A/C Ready Kit, 51950UThe A/C Ready Kit adds air conditioning capability to an existing furnace or boiler.GeniSys Docking Station, 52049UThe GeniSys Docking Station provides the ability to give power to the GeniSys Control when it is not attached to a burner. The Docking Station is also a great training tool giving the ability to simulate burner operation.GeniSys Universal Control Kit, 52097UBeckett has combined all of the accessories for the GeniSys control into a convenient and durable toolbox. Stock the GeniSys Universal Control Kit on your truck and you can replace almost any burner primary control on the market. Included in the Kit are:(2) GeniSys Advanced Burner Controls, (1) GeniSys Contractor Tool – programming and diagnostic tool, (1) GeniSys Lockout Alarm – snap on module to provide dry contacts, (1) AC Ready Kit – burner mounted kit to add AC to a furnace or boiler.
PARTS & ACCESSORIESGeniSys Universal Solutions Product SheetProduct DescriptionThe Beckett GeniSys™ Advanced Burner Control is a 120 Vac primary safety control for residential and light commercial oil burners used in boiler, furnace, and water heater applications. The GeniSys is used with a suitable cad cell flame sensor to control the oil burner motor, igniter, and optional solenoid valve.
It has 24 Vac thermostat terminals (if applicable) compatible with both mechanical and many power stealing thermostats. It can provide interrupted or intermittent duty ignition, and it has a 15-secondlockout time. GeniSys Control Cross-ReferenceChartBeckettLockoutValve-onMotor-offReplacesReplacesGeniSys ControlDelayDelayTimeHoneywell:Carlin:Part No.Time 2Time 27505A 000015 sec-R7184A, R8184G48245, 0,5B 150015 sec15 sec-R7184B-7505P 151515 sec15 sec15 secR7184P, R7184U 15P 153015 sec15 sec30 secR7184P, R7184U 15P 152M15 sec15 sec2 minR7184P, R7184U 160200 11) Beckett snap-inalarm module required for direct replacement of the control.2) Valve-ondelay and motor-offdelay timings on all models are programmable with Beckett snap-inprogramming display. Other factory set timings are available. Contact Beckett for alternate timings.GeniSys Display, 52067UThe GeniSys Display enables the contractor to access the advanced features of the GeniSys Burner Control. It communicates the current status and last fifteen cycles of history for ease of diagnostics.
The Tool also allows the contractor to program the pretime and post-timedelay timings, making the GeniSys a universal control.GeniSys Contractor Tool, 52082UThe GeniSys Contractor Tool, with its sturdy shock absorbing design, is made for the contractor’s toolbox. The Tool provides the same functions as the GeniSys Display.GeniSys Lockout Alarm, 52040UThe GeniSys Lockout Alarm provides dry contacts for use with an alarm system requiring contact closure in the event of a soft or hard lockout of the GeniSys Control.A/C Ready Kit, 51950UThe A/C Ready Kit adds air conditioning capability to an existing furnace or boiler.GeniSys Docking Station, 52049UThe GeniSys Docking Station provides the ability to give power to the GeniSys Control when it is not attached to a burner. The Docking Station is also a great training tool giving the ability to simulate burner operation.GeniSys Universal Control Kit, 52097UBeckett has combined all of the accessories for the GeniSys control into a convenient and durable toolbox. Stock the GeniSys Universal Control Kit on your truck and you can replace almost any burner primary control on the market.
Included in the Kit are:(2) GeniSys Advanced Burner Controls, (1) GeniSys Contractor Tool – programming and diagnostic tool, (1) GeniSys Lockout Alarm – snap on module to provide dry contacts, (1) AC Ready Kit – burner mounted kit to add AC to a furnace or boiler.